IMPLANT TORQUE · HIOSSEN

Hiossen torque values.

One implant site. Five moments where a number decides whether the screw holds: placement, healing, abutment, prosthesis, re-tightening. Every value below is quoted from Hiossen documentation, with the document named beside it.

Scale 0–70 Ncm. Select a component to move the pointer. Values beyond the scale sit at its end.
CONNECTIONSET / EK internal conical hex — mini and regular platforms · SS (Octa) · EM
LINES COVEREDET III SA · ET III NH · EK · SS · EM · Multi Abutment · Multi Angled Abutment
TrazaLabTORQUE SCALE HiossenManufacturer document
EDITORIAL VISUALIZATION
≤ 40Ncm
PLACEMENTET · EK drilling protocol — no numeric maximum published

“The recommended drill speed is 800–1,200 RPM, with an implant insertion torque of ≤ 40 Ncm.” A manufacturer maximum is not printed in the documents we read.

DRIVERFixture mount · torque wrench
Hiossen 2026 Product Catalog — US edition (PC26HPCLTR1.1, 05.2026)

THE VALUES

Every component, its number, its document.

Rows are grouped in treatment order. Where Hiossen publishes a hand-tight instruction instead of a number, the row says so. Where nothing is published, the row says that too.

ComponentApplies toTorqueFrom the documentSource
PlacementInsertion torque of the fixtureET · EK drilling protocol — no numeric maximum published
Driver: Fixture mount · torque wrench
≤ 40Ncm“The recommended drill speed is 800–1,200 RPM, with an implant insertion torque of ≤ 40 Ncm.” A manufacturer maximum is not printed in the documents we read.Hiossen 2026 Product Catalog — US edition (PC26HPCLTR1.1, 05.2026)Manufacturer document
HealingHealing abutment · cover screwHealing abutment — hand tighten (ET III brochure: 5–8)
Driver: 1.2 hex hand driver · 0.9 hex for OB2 / OB3 caps
hand-tight2026 catalog: “Healing Abutment — Hand tighten.” ET III brochure (2017): “Tightening torque: 5–8 Ncm.” OB healing caps: “Use 0.9 Hex Hand Driver … Recommended tightening torque: 5–8 Ncm · Disposable. Single use only.”Hiossen 2026 Product Catalog — US edition (PC26HPCLTR1.1, 05.2026)Manufacturer document
AbutmentFinal abutment screw at implant levelFinal abutment screw — mini 20 · regular 30 (Transfer, Angled, Rigid, Cast, CAD/CAM Ti-base)
Driver: 1.2 hex driver
20 · 30Ncm“Recommended tightening torque: Mini: 20 Ncm — Regular: 30 Ncm.” “After connecting, make sure that it is tightened with a torque wrench.” Torque driver: “30 Ncm (excessive torque causes fracture)”.Hiossen 2026 Product Catalog — US edition (PC26HPCLTR1.1, 05.2026)Manufacturer document
Multi-unitMulti-unit abutment into the implantMulti Abutment straight 30 (mini + regular) · Multi Angled Abutment mini 20, regular 30
Driver: Multi Abutment Outer Driver Pin-Type (MAODP) · 1.2 hex (angled)
30 · 20Ncm“Torque using Multi Abutment Outer Driver Pin-Type (MAODP) … Recommended tightening torque: 30 Ncm (Mini + Regular).” “Multi Angled Abutment … 1.2 Hex Hand Driver · Recommended tightening torque: Mini: 20 Ncm — Regular: 30 Ncm.”Hiossen 2026 Product Catalog — US edition (PC26HPCLTR1.1, 05.2026)Manufacturer document
Prosthetic screwScrew that holds the prosthesis on the abutmentMulti Combination Cylinder · Esthetic-low cylinders · Multi Temporary Cylinder · Multi Ti-Base
Driver: 1.2 hex driver
20Ncm“Component for Multi Abutment … Torque using 1.2 Hex Driver · Recommended tightening torque: 20 Ncm · Packing unit: Cylinder + Ti Cylinder Screw.”Hiossen 2026 Product Catalog — US edition (PC26HPCLTR1.1, 05.2026)Manufacturer document
TemporaryTemporary abutment or copingTemporary Abutment — mini and regular
Driver: 1.2 hex driver
20Ncm“Temporary Abutment … 1.2 Hex … tightening torque: 20 Ncm (mini / regular).”Hiossen 2026 Product Catalog — US edition (PC26HPCLTR1.1, 05.2026)Manufacturer document

Re-tightening, as the manufacturer states it

Hiossen states no re-tightening interval in the 2026 catalog or the ET III brochure we read.

Values are quoted from manufacturer documentation and can change by component, platform and revision. Confirm the IFU for the component and lot in your hand before torquing.

WHY THE SCREW LOOSENS

You torqued it. Then the metal settled.

Torque creates preload — the clamping force that keeps abutment and implant pressed together. Microscopic peaks on the thread surfaces flatten under that load, and part of the preload is gone before the patient leaves the chair. The literature calls it the settling effect, or embedment relaxation.

PRELOAD
The wrench clicks at the manufacturer’s value.

Preload

EDITORIAL VISUALIZATION

ONE SITE, FIVE MOMENTS

Where the numbers appear in the treatment.

Site 36, one fixture, one crown. The same Hiossen values from the table, placed on the moment each one is read off the wrench.

EDITORIAL VISUALIZATION
  1. 01PLACEMENT≤ 40NcmFixture seated

    ET · EK drilling protocol — no numeric maximum published

  2. 02HEALINGhand-tightHealing abutment on

    Healing abutment — hand tighten (ET III brochure: 5–8)

  3. 03ABUTMENT20 · 30NcmFinal abutment torqued

    Final abutment screw — mini 20 · regular 30 (Transfer, Angled, Rigid, Cast, CAD/CAM Ti-base)

  4. 04PROSTHESIS20NcmCrown screw seated

    Multi Combination Cylinder · Esthetic-low cylinders · Multi Temporary Cylinder · Multi Ti-Base

  5. 05RE-TIGHTENING20 · 30NcmSame value, second pass

    Final abutment screw — mini 20 · regular 30 (Transfer, Angled, Rigid, Cast, CAD/CAM Ti-base)

Shown as the same value as the abutment row. Whether and when to re-tighten follows the manufacturer statement quoted in the values section.

AFTER THE CLICK

The value you applied is the value the laboratory should read.

In TrazaLab the implant line on a tooth site keeps system, platform, connection, abutment and applied torque together. It travels into the Digital Rx and onto the laboratory’s per-tooth sheet. An unconfirmed torque is not blank — the laboratory sees it as a gap.

See the Digital Rx
TrazaLabTREATMENT DESIGN · TOOTH 36Digital Rx
TREATMENT DESIGN · TOOTH 36
IMPLANT SYSTEMHiossen
PLATFORMET III SA
CONNECTIONET / EK internal conical hex — mini and regular platforms
ABUTMENTFinal abutment
TORQUE APPLIED20 · 30 Ncm
DIGITAL RXTorque applied · 20 · 30 Ncm
LABORATORY · PER-TOOTH SHEET36 · implant crown · torque 20 · 30 Ncm

QUESTIONS

Asked before the wrench is set.

Values are quoted from manufacturer documentation and can change by component, platform and revision. Confirm the IFU for the component and lot in your hand before torquing.

01Are Hiossen and Osstem torque values the same?+

For the values we read, yes: mini 20 Ncm and regular 30 Ncm for the final abutment, 30 Ncm for the straight Multi Abutment, 20 Ncm for the cylinder screw, hand-tight healing components, and 40 Ncm or less at placement. Hiossen is Osstem’s US catalog. The document that ships with your component still decides.

02What is the multi-unit cylinder torque on a Hiossen Multi Abutment?+

20 Ncm with the 1.2 hex driver, for the Multi Combination Cylinder, the Esthetic-low gold and plastic cylinders, the Multi Temporary Cylinder and the Multi Ti-Base. The Multi Abutment itself goes on at 30 Ncm with the pin-type outer driver.

03Do these Hiossen values replace the IFU?+

No. They are quoted from the manufacturer documents listed on this page, with the revision year noted. The IFU packed with your component and lot is the instruction; this page puts the values next to the treatment step and the case record.

04Should I re-tighten after ten minutes?+

The literature on the settling effect widely advocates a second application at the same value after about ten minutes, and in vitro work shows it partially restores preload. The evidence for a fixed interval is limited. The manufacturer statement for this system is quoted in the values section; where it says nothing, this page does not turn that silence into a rule.

05Where does the applied torque go after the appointment?+

In TrazaLab it is a field on the implant line of the tooth site, next to system, platform, connection and abutment. The Digital Rx carries it to the laboratory, whose per-tooth sheet prints the torque. If it was never confirmed, the packet shows “Not on Rx” instead of a number.

AFTER THE CLICK

Read the value here. Keep it in the case.

TrazaLab records the implant line with its torque on the tooth site, writes it into the Digital Rx, and shows the laboratory exactly what was applied — or exactly what was not confirmed.

Choose the right next step

Start with one case.

Create an account now or walk through a complete case before deciding. Both paths are available today.

Already using TrazaLab? Log in

Choose based on what you need

ACCOUNTStart nowCreate an account through the functioning TrazaLab signup journey.
TOURUnderstand before decidingFollow the complete self-guided case without registration or a sales conversation.
CASECompare it with your flowUse the tour as a guide and activate TrazaLab when the process fits your team.